/ Fire Pumps
UL Listed & FM Approved Fire Pumps in Egypt
YAMA Engineering Systems supplies the complete range of UL Listed and FM Approved fire pumps for commercial, industrial, and high-rise applications across Egypt. Every package is offered in both electric motor and diesel engine configurations and is engineered to fully comply with NFPA 20 — from the pump and driver to the controller and enclosure — so the entire fire pump set is certified as one listed assembly, not a collection of separate parts.
As the official distributor of Pentair Fairbanks Nijhuis and Bristol fire pumps in Egypt, we select each unit against your actual system curve — verifying duty point, NPSH margin, and motor service factor — before any equipment is finalized.







UL Listed & FM Approved Fire Pumps in Egypt
Horizontal Split Case Fire Pumps
Vertical Turbine Fire Pump
End Suction Fire Pump
Technical Specifications:
Flow Range: 250 to 8000 GPM
Pressure Range: 40 – 435 PSI
Drive Options: Electric Motor / Diesel Engine
Casing Materials: Heavy-duty Cast Iron / Corrosion-resistant Bronze
Standards & Certifications: NFPA 20 compliant, UL 448 Listed, FM Approved
Product Description: This is the most common fire pump configuration utilized for high-rise buildings, industrial manufacturing plants, and large-scale commercial facilities in Egypt. The specialized horizontal split casing allows engineering teams to perform easy internal inspections and rapid impeller replacements without disconnecting or removing the pump from the main system piping.
Technical Specifications:
Flow Range: 250 – 4,500 GPM
Pressure Range: 50 – 370 PSI
Drive Options: Electric Motor / Diesel Engine
Bowl Material: Heavy-duty Cast Iron / Grade Stainless Steel
Standards & Certifications: NFPA 20 compliant, UL 448 Listed, FM Approved
Product Description: This specialized fire pump configuration is mandatory when the primary water source is located below ground level—such as deep wells, water tanks, or underground reservoirs. Frequently deployed across massive industrial complexes, power generation plants, and water treatment facilities in Egypt, its advanced multi-stage configuration reliably delivers high pressure from deep water sources.
Technical Specifications:
Flow Range: 100 to 2,500 GPM
Pressure Range: 40 – 225 PSI
Drive Options: Electric Motor / Diesel Engine
Mounting Configurations: Close-coupled / Frame-mounted
Standards & Certifications: NFPA 20 compliant, UL 448 Listed, FM Approved
Product Description: This is a compact, cost-effective fire pump configuration engineered specifically for low-to-medium flow applications. It serves as the ideal fire protection choice for commercial warehouses, mid-rise buildings, and industrial facilities across Egypt. The single-suction design significantly reduces the required installation space and simplifies long-term engineering maintenance.
supplies the complete range of UL Listed and FM Approved fire pumps for commercial, industrial, and high-rise applications across Egypt. Every package is offered in both electric motor and diesel engine configurations and is engineered to fully comply with NFPA 20 — from the pump and driver to the controller and enclosure — so the entire fire pump set is certified as one listed assembly, not a collection of separate parts.
As the official distributor of Pentair Fairbanks Nijhuis and Bristol fire pumps in Egypt, we select each unit against your actual system curve — verifying duty point, NPSH margin, and motor service factor — before any equipment is finalized.
Electric Motor & Diesel Engine
Each of the three pump types above is available with two driver configurations. Most critical facilities install both — an electric pump as the primary unit and a diesel pump as the standby — so protection is maintained even during a total power failure.
Electric Motor Driven Fire Pumps
Powered by a UL/FM listed fire pump motor sized to carry the pump across its full curve at the rated service factor. Suitable for any site with a reliable, dedicated power supply backed by an emergency source or a diesel standby pump.
• Motor Brands: WEG · U.S. Motors (USEM / Nidec)
• Features: UL/FM listed motors, high service factor, multiple voltage and pole options, paired with a listed electric fire pump controller.
Diesel Engine Driven Fire Pumps
A self-contained driver that runs independently of the electrical grid — mandatory backup for hospitals, data centers, and critical infrastructure that cannot lose fire protection during an outage. Each set includes a listed engine, dedicated fuel tank, dual-battery starting redundancy, and a closed-loop heat-exchanger cooling system.
• Engine Brands: Clarke · Kirloskar (KOEL)
• Features: UL/FM listed diesel engines, heat-exchanger cooled, dual battery banks, integral fuel tank, paired with a listed diesel fire pump controller.
Fire Pump Controllers & Enclosures
Under NFPA 20 the controller is part of the listed fire pump assembly. We supply UL Listed and FM Approved controllers, matched to the driver type and to the site environment through the correct NEMA enclosure rating.
Approved Controllers
• Brands: Tornatech · Firetrol
• Electric Fire Pump Controllers — across-the-line, soft-start, or variable-speed, with an optional integral or separate Automatic Transfer Switch (ATS) for emergency power changeover.
• Diesel Fire Pump Controllers — automatic/manual start, dual-battery charging and monitoring, with full alarm and signal contacts.
Enclosure Ratings (NEMA)
The enclosure is selected to match the installation environment — indoor pump room, washdown area, outdoor skid, or corrosive/coastal location.
Technical Specifications
NEMA 2: Drip-proof, indoor — Standard indoor pump room (default)
NEMA 3R: Rain / sleet, outdoor — Outdoor or sheltered installations
NEMA 4: Watertight, hose-directed water — Washdown areas, exposed locations
NEMA 4X: Watertight + corrosion resistant — Coastal, chemical, high-humidity sites
NEMA 12: Dust-tight, industrial — Dusty industrial environments
Jockey (Pressure Maintenance) Pumps
A Jockey Pump keeps the fire suppression network pressurized at all times. It starts automatically on a small pressure drop from minor leaks or fluctuations, preventing the main fire pump from cycling unnecessarily—a strict requirement of NFPA 20 for wet-pipe systems.
Typically designed as a vertical multistage unit, it is precisely sized to make up small pressure losses without meeting any actual fire demand, ensuring your main system remains protected and ready for true emergencies.
Technical Specifications
Capacity: Up to 210 GPM
Pressure: Up to 330 PSI
Purpose: System standby pressure maintenance
Activation: Automatic on inline pressure drop
Standards: Fully NFPA 20 compliant
Non-UL Listed Fire Pumps
For private developments, small-scale structures, and light industrial facilities where the authority having jurisdiction does not require UL/FM listing, we supply project-engineered non-listed fire pumps. These deliver dependable performance at an optimized budget while still being selected and verified against the project’s hydraulic requirements.
Technical Specifications
Flow Range: 250 – 750 GPM
Pressure Range: Up to 145 PSI
Drive Options: Electric Motor / Diesel Engine
Sourcing: Official factory distribution / global suppliers
Basis: Project-specific engineered / localized performance
Give Us the Flow Rate and Pressure
Send us your application parameters — GPM, TDH, fluid temperature, and duty cycle — and our engineering team returns a fully specified pump selection with curve data within one business day.












Duty Verified, Not Approximated
Technical Specifications:
Primary Brands: Pentair Fairbanks / Bristol Fire Pumps Sourcing Options: Multi-Brand Sourcing / Global Manufacturer Logistics Service Options: Full Hydraulic Verification / System Curve Review Performance Metrics: Certified Operating Duty / Optimum NPSH Margin Project Handover: Official Testing Records / Commissioning Certificates
Product Description We supply any leading international brand based on project specifications while focusing on premium Pentair Fairbanks and Bristol fire pumps as the official distributor in Egypt. Our dedicated engineering teams thoroughly review your specific system curve to verify actual operational duty, motor service factors, and critical suction heads before finalizing any equipment selection across the Egyptian market.
Give Us the Flow Rate and Pressure
Submit your application parameters — GPM, TDH, fluid temperature, and duty cycle. We return a fully specified pump selection with curve data within one business day.
